ALMEMO 2090-1 Spotlight:
Temperature measuring instrument for thermocouples and Pt100-sensors, sensors with mV- or V-output, 1 measuring input, without output
2096-1 Spotlight:
Measuring instrument for NTC temperature sensors, thermocouples and capacitive humidity sensors, sensoren with mV- or V-output, 1 measuring input, without output
2190-2 Spotlight:
Measuring instrument for all ALMEMO¢ē-sensors, 1 measuring input, 2 measuring channels (selection of measuring point by means of slide switch at the side), 1 output socket for analog output module ZA 1601 RK
2290-1 Spotlight:
Universal measuring instrument for all ALMEMO¢ē-sensors 1 measuring input, 2 measuring channels (selection of measuring point by means of slide switch at the side), 2 output sockets for analog or interface module
2290-2 Spotlight:
Universal measuring instrument for all ALMEMO¢ē-sensors 1 measuring input, 2 measuring channels (up to 4 meas. channels callable via keyboard) 2 output sockets for analog or interface module
2290-3 Spotlight:
Difference measuring instrument for all ALMEMO¢ē-sensors, 2 measuring input, galv. sep., 3 measuring channels (up to 3 max. meas. values callable via keyboard),
2 difference measuring channels, 2 output sockets for analog or interface module
2295-6 Spotlight:
Special measuring instrument for HEVAC-applications, 5 measuring inputs, 9 measuring channles, 2 output sockets for analog or interface module
2290-8 Spotlight:
Universal measuring instrument and portable datalogger for all applications, 5 measuring inputs galv. sep., up to 10 measuring channels, 2 output sockets for analog or interface module
3290-8 Spotlight:
Universal measuring instrument and datalogger for all applications in table version, (W125 x H 70 x D 185 mm, 2000 g)
9 measuring inputs galv. sep., up to 18 measuring channels, 2 output sockets for analog or interface module
4290-7 Spotlight:
Datenlogger in wall housing for all applications, where documentation of measured values is required, for all measuring ranges, 5 measuring inputs galv. sep., 10 measuring channels, 2 output sockets for analog or interface module, system of protection IP42 Special version with Pt100 measuring range for monitoring cold storage rooms according to guideline 92/1/EWG, special software on demand
6290-7 Spotlight:
Compact, battery-operated measuring instrument with built-in printer for graphical and alphanumerical recording of measurements, for all applications 2 measuring inputs, output socket for analog module or RS232 interface cable
8990-8 Spotlight:
Universal datenlogger with memory for data acquisition ON- and OFFLINE, plastic housing (W 135 x H 69 x D 226 mm) 9 measuring inputs galv. sep., upto 18 measuring channels, 2 output sockets for analog or interface module
8990-6 Spotlight:
Universal datalogger without mnemory for ONLINE data acquisition, plastic housing (W135 x H69 x D226 mm), measuring inputs galv. sep., upto 18 measuring channels, 2 output sockets for analog or interface module
5590-1 Spotlight:
Universal datalogger without memory in modular 19"-rack-mounting.
It offers the possibility to combine several measuring modules 8990-6 in one housing
5590-2 Spotlight:
Precision measuring instrument and data acquisition system for all measuring ranges All ALMEMO¢ē-functions are incorporated in this top instrument.
5590-3 Spotlight:
Data acquisition system with own CPU for self-sufficiant adminsístration of several active measuring channel scanner modules and any external device. Up to 300 measuring can be acquired, administrated and stored even without a PC. The data memory of 520 kB can be expanded up to 2 MB. The CPU is equipped with interfaces to the internal bus, 1 output for embedding in an external network, as well as 2 output sockets for data output and networking with other ALMEMO¢ē-instruments, additionally a Centronics-interface for a printer, e.g. to printout the programming or off-normal values. Operation is effected by means of the rotary switch and the keyboard. Two-ligned alphanumerical LCD-display for simultanious display of measured values and measurement function.
6290-7K Spotlight:
Compact, battery-operated measuring instrument or datalogger with ring memory with built-in printer for graphic or alphanumeric recording of temperature and relative humidity. Especially suited for data recording e. g. in climatic test chambers, climatic rooms, museums, galleries, computer rooms, clean rooms and for judging on historical buildings protected and in need for renovation.
2296-1K Spotlight:
Climate measuring instrument with double display and top hat rail fastening. 1 measuring input for temperature and humidity, 2 output sockets for networking or PC-connection for ONLINE-measurement and OFFLINE-evaluation
4490-2 Spotlight:
Intelligent panel mounted instrument with 4-digit LED-dispaly (measured values with more than 4 digits are available at the output, however), 1 ALMEMO¢ē measuring input (up to 4 measuring channels), 1 strip terminal, cascadable RS232-interface, data output in spread sheet format, power supply 230 V / AC Panel mounted instrument ALMEMO¢ē 4490-2GV as described above but with standard plastic housing 96 x 96 mm, mounting depth 160 mm panel curring 90 x 90 mm, additionally with sensor supply 12 and 24V DC / 500 mA
8990-1 Spotlight:
Intelligent transmitter in aluminium housing (105 x 44 x 132 mm) power supply 12 V / DC , 1 ALMEMO¢ē measuring input (up to 4 measuring channels), 1 strip terminal (1 channel), 2 ALMEMO¢ē output sockets, cascadable RS485-interface, ata output in spread sheet format