Facility Monitoring Particle Counter

Monitoring manufacturing environments has never been more affordable!  The FMPC has palm-top dimensions. It is wall-mounted close to the critical process and provides continuous monitoring with unparalleled accuracy and reliability.  The host computer sets all measuring parameters, and data is continuously collected via RS-485 with a standard T-568 B cable over distances up to 100 feet and more. The FMPC can also be used with most commercially available process control and facility monitoring software.

View Specs

 

¡¡

Features 

  • 2 Channel: 0.3um, 0.5um
  • 0.1 cfm (2.83 l/min.)
  • Meets Japanese Industrial Standards
  • RS-485 or pulse mode interface

¡¡

FMPC Specifications

2 Size Channels 0.3µm; 0.5µm 
Flow Rate 0.1 CFM (2.83 L/min)
Light Source Laser Diode; Index Guided
Vacuum Source Critical Orfice requires > 18 in. Hg vacuum
Inlet Pressure Ambient to 0.1 Hg vacuum
MBTF at 25¡ÆC Ambient >36,000 hours
Calibration PSL particles in air (NIST Traceable)
Counting Efficiency 50% @ 0.3µm; 100% for particles > 0.45 µm (per JIS B9921)
Zero Count < 1 count/5 minute (per JIS B9921)
Coincidence Loss 5% at 2,000,000 particles per ft3
Interface RS-485 via RJ-45, Pulse mode
Indicators Power and Calibration LED's
Dimensions 4.192¡± (l) x 2.663¡± (h) x 1.618¡± (w)
Weight Approx. 12oz.
Power Requirements 9-28 VDC (100mA @24V max.)

Operating Conditions

Relative Humidity 20% to 95% relative humidity, non-condensing
Temperature 10¡ÆC to 40¡ÆC (50¡ÆF to 104¡ÆF)
Storage Conditions
Relative Humidity Up to 98% relative humidity, non-condensing
Temperature -10¡ÆC to 50¡ÆC (14¡ÆF to 122¡ÆF)
Standards

      JIS B9921

¡¡