VSE 3000 Volume Static Eliminator


click on image for larger view

Patented ESD Workstation Ionizer - Effectively eliminates static charges on your work bench quickly and reliably. The VSE 3000 was the first ionizer designed to the testing procedures established by ANSI EOS/ESD Standard 3.1, the accepted industry standard for ionizer testing.
The Standard-Setter in Benchtop Ionizers

Performance: Your entire workstation is flooded with static eliminating ions delivered by the VSE 3000’s variable speed fan and integral air flow diffuser. No other benchtop ionizer gives you faster static decay rates over your entire work surface.

Reliability: Protecting ESD-sensitive components requires tight, reliable ion balance. The VSE 3000 has patented, self-balancing circuitry that maintains a balance window of 0±5 volts. The VSE’s balance is maintained even during the brownouts and voltage fluctuations that cause other ionizers to operate out of balance.

Convenience: Exceptionally quiet, the VSE 3000 delivers a powerful air flow with low noise levels thanks to sophisticated sound absorbing materials. A separately controlled heater provides operator comfort. The VSE 3000’s support stand requires minimal workbench area, and can be mounted overhead or on walls or pedestals.

An optional adjustable height stand is available for maximum mounting flexibility (see I-VSE 5000).

 




click on diagram for larger view

VSE 3000 DECAY TIMES

1 ft 24.5 sec 0.8 sec 23.5 sec
2 ft 5.8 sec 1.6 sec 5.5 sec
3 ft 5.3 sec 2.8 sec 5.5 sec
4 ft 6.0 sec 3.8 sec 7.3 sec
1 ft Center Line 1 ft
Time required to decay a 20pF plate from 1000v to 100v per EOS/ESD-S3.1


SPECIFICATIONS

Ion Balance: Self balancing unit maintains 0±5 volts balance at all normal operating conditions
Air Volume: Variable 38 to 76 liters/sec (80 to 160 cubic ft/min)
Air Velocity 2.8m/sec at 0.6 meters (550ft/min at 2ft) at maximum fan speed
Angle of Ionized Air Coverage: 60 degrees
Heated Air

-at Maximum Airflow

-at Minimum Airflow


4.4 degree C (8 degree F) rise above ambient

8.8 degree C (16 degree F) rise above ambient
Noise Level: 63 dbA max at 0.6 meters (2 ft) at maximum fan speed
Ozone: Per UL 867 requirements
EMI/RFI: Complies with FCC Part 15 requirements for Class A equipment
Dimensions: 254 x 305 x 159mm (L x W x H) (10 x 12 x 6.25in)
Footprint of Stand: 324 x 140mm (12.75 x 5.5in)
Weight: 3.6kg (8lbs)
Line Voltage: 115 VAC or 230 VAC, 50/60 Hz
Power: 35 watts with heater off; 435 watts with heater on
Fuse: 115 VAC unit supplied with 5 amp fues; 230 VAC unit supplied with 2.5 amp fuse
CE Compliant: Yes, Order Part Number 10735-014
Easily accessible
Cleaning brush included to clean the emitter points for maximum neutralization.
User friendly control panel
Heater can be switched on or off separately from main power switch. Infinitely variable fan speed control.
Removable emitter assembly ­ offered only by Chapman
Routine cleaning requires no disassembly. Simply brush the emitter points with the brush included with every unit. For thorough cleaning of the points and air channel, the emitter assembly is removed. And after many years of use, replace the emitter assembly for a like-new unit!


ORDERING INFORMATION

Product # Description
10735-001 VSE 3000, 115 volt, North American plug
10735-002 VSE 3000, 230 volt, North American plug
10735-003 VSE 3000, 230 volt, European (Schuko) plug
10735-014 VSE 3000, 115 volt, European (Schuko) plug, CE Compliant
Optional Equipment
11138-001 Adjustable Height Stand
10631-001 Emitter Assembly (>50,000 hours life)
10790 Filter Kit (5 filters and holder)
10757 Filter replacements