ITEM
|
SPEC
|
REMARKS
|
|
Model:
MMS3000-T4
Incorporating 4 Temperature Channels
|
|
TEMPERATURE
RANGE
|
T
Type Thermocouple
|
-418 to
+743¡ÆF (-250 to +395¡ÆC)
|
Operating
temperature range
|
E
Type Thermocouple
|
-418 to
+1823¡ÆF (-250 to +995¡ÆC)
|
is
determined by operating
|
J
Type Thermocouple
|
-346 to
+2183¡ÆF (-210 to +1195¡ÆC)
|
range
of thermocouple
|
K
Type Thermocouple
|
-418 to
+2498¡ÆF (-250 to +1370¡ÆC)
|
|
TEMPERATURE
RESOLUTION
|
|
Above
-148¡ÆF (-100¡ÆC): 0.1¡ÆF or ¡ÆC
|
|
|
At or
below -148¡ÆF (-100¡ÆC): 1¡ÆF or ¡ÆC
|
Effective
resolution decreases at or below -148¡ÆF (-100¡ÆC)
|
TEMPERATURE
ACCURACY
|
|
Above
-148¡ÆF (-100¡ÆC): ¡¾0.1% of reading ¡¾0.9¡ÆF (0.5¡ÆC)
At or below -148¡ÆF (-100¡ÆC): ¡¾1% of reading ¡¾0.9¡ÆF (0.5¡ÆC)
|
Total
measurement accuracy depends on MMS3000-T4 and thermocouple
accuracy. Only MMS3000-T4 accuracy is given here. MMS3000-T4
temperature 73 ¡¾ 9¡ÆF (23 ¡¾ 5¡ÆC), charger off. See Appendix 3
of Owners Manual
|
MINIMUM
SAMPLING INTERVAL
|
|
#
of channels selected
(User-selectable)
|
Minimum
sampling interval
(seconds)
|
1
|
0.2
|
2
|
0.3
|
3
|
0.5
|
4
|
0.6
|
|
Sampling
interval is programmable from 0.2 seconds to 60 hours
Note: Minimum time to scan all selected channels - not each
channel
|
DATA
LOGGING
|
Data
Storage
|
512
kilobytes – approx. 400,000 individual samples
|
Non-volatile
memory (with battery back-up). # of Samples depends on # of Data
Sets and Recordings.
|
Data
Storage Format
|
Up to 50
named DATA SETS
|
User-specified
name entered from keypad
|
|
Up to 50
RECORDINGS per data set
|
Each
recording has unique time/date stamp
|
|
Up to
9,999 SAMPLES per recording
|
Each
sample contains data for all selected channels
|
Data
Set Name
|
Up to 16
alpha-numeric characters
|
|
DISPLAY
|
|
LCD with
graphic capabilities
|
|
Resolution
|
240 x
128 pixels
|
|
Viewing
Area
|
4.3"
x 2.3" (110mm x 60mm)
|
|
Backlight
|
Electro-luminescent
|
|
PROFLASH
|
|
Allows
internal firmware to be upgraded via built-in RS232 port
|
Download
firmware upgrades via the Internet
|
COMMUNICATIONS
|
|
RS232
|
15kV
ESD Protected. Cable with DB9 connector included
|
Baud
Rate
|
9600,
19200, 57600 bits per second
|
Automatic
Baud Rate Selection
|
INPUT
TERMINATION
|
|
Sockets
accept miniature thermocouple twin blade plug
|
Blades
spaced 5/16" (7.9mm) center-to-center
|
INPUT
IMPEDANCE
|
|
Greater
than 100k Ohms
|
Terminal-to-terminal
|
ISOLATION
|
|
50VDC
minimum
|
Between
temperature inputs and MMS3000-T4 outputs e.g. RS232 port. No
isolation between input channels.
|
BATTERY
|
Type
|
Custom
Nickel-Cadmium pack
|
|
Voltage
|
7.2
Volts nominal
|
|
Capacity
|
1500 mAh
nominal
|
|
Operating
Time
|
13 hrs
with backlight off, 7 hrs backlight on - nominal
|
|
CHARGER
AND CONDITIONER
|
|
Built-in
dual rate charger – Automatic and Manual control
|
AC
Adapter included (13.5 ¡¾ 1.5 VDC, 1A output)
|
Fast
Charge Rate
|
0.7A
nominal
|
2.5
hours for complete charge nominal
|
Discharge
Rate
|
0.5A
nominal
|
Combats
NiCad battery memory effect
|
MECHANICAL
|
Size
|
9.7"W
x 6.1"L x 3.0"H (247mm x 154mm x 75mm)
|
Including
protective boot
|
Weight
|
4.4lb
(2kg)
|
Including
protective boot and strap
|
ENVIRONMENTAL
|
Temperature/Humidity
|
|
|
Operating
|
32¡ÆF to
122¡ÆF (0¡ÆC to 50¡ÆC) / 70% RH
|
Non-condensing
|
|
32¡ÆF to
86¡ÆF (0¡ÆC to 30¡ÆC) / 80% RH
|
Non-condensing
|
Storage
|
14¡ÆF to
140¡ÆF (-10¡ÆC to 60¡ÆC ) / 95% RH
|
|
EMC
|
EN50081-1
|
Radiated
and conducted emissions
|
|
EN50082-1
|
ESD
Immunity and RF field immunity (EMI).
|
The
manufacturer reserves the right to modify specifications without
prior notice.
|