The
dipper-T water level meter is accurate, reliable, and economical.
The dipper-T uses the same ergonomically designed reel that is
used for the Heron interface meter. The tape on the dipper-T
conforms to US GGG-T-106E, a guarantee of accuracy. A cascade proof 5/8
in(16mm) dia probe is attached to the tape by a strong flexible link
that protects the tape at this vulnerable point. The wetted parts of the
probe are stainless steel and Teflon¢ç. The instrument is used to
accurately measure the static water level in boreholes, wells, and
standpipes and can be used to monitor water level changes during
drawdown tests. The dipper-T is the basic tool for well drillers,
hydrogeologists and any other professional concerned with the study of
groundwater.
FEATURES
- Durable
UV and high impact resistant engineered plastic reel with all
stainless steel fittings
- Polyester
coated steel frame with a comfortable vinyl grip and "third
hand" built in casing hanger lets you hang the unit on the well
while you record results
- Large
ergonomic
brake and winding handle
- Water
and dust proof encapsulated electronics on a removable front panel
- Full
depth stainless steel and Teflon ¢ç probe
- Flexible
link between the tape and probe
- Accurate
(complies
with US GGG-T-106E standards) medium density
polyethylene jacketed tape with stretch proof stainless steel
conductors
- The
standard tapes are marked in feet and 100th/ft or meters and mm
- The tape
lengths are 60ft, 100ft, 150ft and 200ft to 2500ft in steps of 100ft
(15m, 30m, 50m, 100m, thereafter in 50m increments). Intermediate
lengths are to special order
- 5 year
limited warranty
- Costs
less than comparable quality units on the market
Note:
400ft (150m) and longer models use aluminum reels for lightness.
AVAILABLE
OPTIONS
Kynar¢ç
and Tefzel¢ç jacketed tape
A tough protective nylon carrying bag
Narrow 3/8" diameter stainless steel and Teflon¢ç probe
TEMPERATURE
 |
Do
You Need To Measure Ground Water Temperature?
Now
you can! With the new temperature option available on the
Dipper-T.
Read
water temperatures from 0¡Æ - 110¡Æc with an accuracy of 0.1¡Æc
displayed directly on an LCD mounted on the control panel.
No hand held readouts, cables or complicated charts needed.
|
¡¡
DIMENSIONS
¡¡
| Reel
Weight |
5lbs
(2kgs) |
| Tape
per 100ft |
1.0lb
(.45kgs) |
| Overall
Height |
13.5
inch (34 cm) |
| Width |
10
inch (25 cm) |
| Depth |
8
inch (20 cm) |
|