| In-Situ
Multi-Parameter TROLL 9000 Water Quality Monitor |
 |
 |
¡¡ |
| ¡¡ |
 |
| |
 |
-
Dissolved Oxygen (% &
mg/L)
- Conductivity, Resistivity, TDS
- Temperature
- pH
- ORP
- Salinity
- Level, Pressure, Depth
- Open channel flow
- Barometric pressure
- Nitrate
- Chloride
- Ammonium, Ammonia
- Turbidity |
|
|

The NEW Standard for Water Quality Monitoring!
In-Situ,
Inc.
Multi-Parameter TROLL 9000 Water Quality Monitor
The new
TROLL 9000 is a lightweight, multi-parameter water quality
monitor that uses the most current sensor and electronics
technology. Capable of monitoring up to 9 parameters
simultaneously, the TROLL 9000 is the ultimate tool for water
quality profiling applications and unattended long-term
deployments. The TROLL 9000 is constructed of 316L stainless
steel, making it rugged, yet lightweight and features many new
technological innovations, such as: Smart Sensors, Digital DO,
Factory Pre-Calibrated Sensors and Single Quick-Calibration
Solutions
The TROLL
9000 interfaces with a Compaq Pocket PC or with any laptop
computer or with a SDI-12 logger for long term data logging. All
memory enabled units ship standard with up to 4 MB of memory for
internal logging of over one million data points.
There a 5
models available, so use the chart at the bottom of this page to
determine which model will best suit your application: Profiler,
Profiler XP, Professional, Professional XP, or LTS.
Japanese information
| - |
Smart
Sensors that are 'Plug and Play'
remember calibration |
| - |
Digital
D.O.™ -- no stirring required. |
| - |
Single
"Quick-Cal" solution --
calibrate most sensors at the same time! |
| - |
The
most sensors in a 45mm (1.75") diameter--
up to 9 sensors |
| - |
Pre-Calibrated
and ready to use -- Ready to use right
out of the box! |
| - |
Flexible
sensor ports -- add sensors of your choice to
any port |
| - |
Small,
lightweight design using high quality 316L
stainless steel |
| - |
Internal
datalogger with up to 4MB
(1,760,000 data points!) |
| - |
User-replaceable,
powerful D batteries provide maximum power --
up to 6 months. |
| - |
Vented
Quick-Connect cable (FEP or Polyurethane) --
Fully detachable! |
| - |
Internal
barometric sensor -- record real-time
barometric changes |
| - |
Networking
and telemetry capable |
| - |
Multiple
product versions -- select features to match
your budget. Always upgradeable! |
|
|
|
|
|
|
|
|
 |
What
makes the MP TROLL 9000 the best choice for water quality
monitoring? |
 |
The
Most Sensors in a 45mm (1.75") diameter body
The TROLL 9000 is the ultimate tool for profiling, surveying and
long-term monitoring. It features the most sensors in a 1.75"
(45mm) housing packing in 5-sensors ports plus temperature and
barometric pressure sensors. The compact design allows for all of the
standard parameters such DO, conductivity, pH, ORP, temperature and
level to measure an additional ISE parameter like pH, ORP, ph/ORP combo,
Nitrate, Chloride, Ammonium. Each sensor has been specially designed by
In-Situ for field use to provide extra long-life and low-drift.
 |
| |
SMART
SENSORS
New "Smart Sensor" technology remembers its calibration so you
won't have to. What does it mean for the sensors to be
"Smart". First, this means that they are ¡®Plug and Play¡¯
meaning -- most sensors can be plugged in any sensor port allowing for
custom or redundant sensor configurations. Second, since they remember
their calibration coefficients, you can calibrate them on a separate
unit (in the office for example) and plug them into completely different
unit (perhaps one that is in the field) without any need for
recalibration. A user may have several sensors that can be simply
rotated among multiple units. Think of it--no need to calibrate in the
field. Just plug them into one of the optional ports and they are ready
to go!
| Most
sensors can be added to any port! |
 |
In-Situ
has revolutionized the way you use sensors. Our Smart Ports™
allow you to create custom or redundant sensor configurations by
adding the sensors of your choice to the port you want.
1.
ISE* (pH, ORP, ph/ORP combo, Nitrate, Chloride,
Ammonium)
2. Dissolved Oxygen or ISE (pH, ORP, Nitrate,
Chloride, Ammonium)
3. ISE (pH, ORP, ph/ORP combo, Nitrate,
Chloride, Ammonium)
4. Conductivity or ISE (pH, ORP, ph/ORP combo,
Nitrate, Chloride, Ammonium)
5. Fixed Port - Pressure, Level, Depth, Open
Channel Flow, Turbidity (when available)
Temperature is standard on all units and Barometric pressure is
optional.
ISE = Ion Selective Electrode (single or
combo e.g. pH/ORP)
For
example, here are two configurations that are possible.
Many more exist!
Example configuration #1: DO, Conductivity,
Temperature, pH/ORP, Nitrate, Level
Example configuration #2: Temperature, pH/ORP,
Nitrate, Chloride, Ammonium
|
| |
|
¡¯DIGITAL¡®
D.O.™ – NO STIRRING REQUIRED!
To stir or not to stir? Thanks to powerful NEW Digital
D.O. technology you can choose either! Use the digital
¡®sleep¡¯ mode for long-term monitoring—NO STIRRING REQUIRED! Or
for extreme accuracy, measure D.O. in continuous ¡®ON¡¯ mode. Any way,
you will get the highest level of accuracy with complete versatility. Is
your D.O. digital?
 |
With
hassle-free removable membrane
caps! |
The
importance of stirring for ISE sensors
Did you know that stirring is not only for DO? Stirring greatly
improves readings from ISE sensors such as pH, ORP, nitrate,
chloride, ammonium, etc. Since ISE sensors use reference gels
and solutions that slowly leach from the sensor into the
solution, it is important to stir the sample to remove these
interferences.
Up to
this time, stirring with field instruments has not be practical
due to the excessive power requirements. Additionally, stirrers
that are currently available on some multi-parameter units are
simply too turbid on the sample to obtain quality measurements.
In-Situ's
Stirrer solves these problems by slowly and deliberately
stirring the sample. It is similar to those recommended for use
in a laboratory providing minimal sample agitation without being
too turbid. Plus, a single user-replaceable D-size alkaline
battery provides power for over 6 months! The result? Laboratory
grade measurements in the field!
|
 |
| |
|
All TROLL
9000¡¯s ship factory pre-calibrated and are ready
to use right out of the box! Each unit is subjected
to intense environmental testing and calibration is certified to NIST
traceable standards. A calibration report is included with every unit.
Plus sensors are automatically compensated real-time. With this peace of
mind, you can spend more time getting data!
| |
|
 |
For
the ultimate in convenience try our ¡°Quick-Cal¡±solutions for
simple, painless calibrations. Simply place the TROLL 9000 in
the solution and press ¡°calibrate¡±—it¡¯s that easy!
Quick-Cal solutions can be used to simultaneously calibrate D.O.,
conductivity, pH and ORP sensors. Traditional calibration
methods are also available. |
Our
Customers and their clients demand accuracy and
precision. All units must pass extensive environmental
testing prior to shipment that is traceable to NIST standards. Our
published specifications are very conservative and reflect our high
regard for the integrity of data in all environmental conditions, not
just the lab. In fact, our specifications include several margins of
error so you have confidence that the TROLL 9000 will perform as
specified. We stand behind our accuracy by providing a calibration
report with EVERY MP TROLL 9000.
|
- |
Resolution:
24-bit A-D converter: 1mm for a 30-psi
sensor |
|
- |
DO
readings are automatically compensated for barometric pressure,
temperature and salinity |
| |
- |
Pressure
Accuracy: 0.1%FS over entire pressure & temperature range |
|
- |
Automatic
Temperature Compensation -- across the full temperature range
from -5 to 50¡ÆC |
|
- |
Temperature
Accuracy: +/- 0.1C over entire range |
|
- |
Fluid
Density Correction |
|
- |
Gravitational
Acceleration Correction |
|
- |
Liquid
Density Correction |
|
- |
NIST-Traceable
Calibration |
|
|
|
A
powerful internal data logger is the key to real-time profiling and
long-term monitoring. The internal logger allows for up to 16 tests to
be scheduled run or completed and stored while a test is running. Four
tests types are available including linear, linear average, event and
logarithmic. With 4MB of onboard memory, you can record
over 1-million data points. The memory is non-volatile
so your memory is always protected even if the power is disconnected.
The low-power circuitry allows the MP TROLL 9000 to be deployed for
months at a time, using off-the shelf alkaline D-Size batteries.
Download
data anytime, even when a test is running--there is no need to stop it.
Only new data is downloaded and is automatically appended to the
original file to save you time. If the data has not be previously
downloaded or if a different computer is attached, the entire file will
be transferred. All test data is stored in memory until removed, even if
another test is running.
| - |
Linear
Tests |
| - |
Linear
Average Tests |
| - |
Event
Tests |
| - |
Log
Tests |
| - |
0.5
second to 7 day user-selectable sampling rates |
| - |
Real-time
crystal clock accurate to +/-2min per year |
| - |
Downloads
only new data |
| - |
Up
to 16 tests scheduled to run or stored |
| - |
Over
1-million data points |
Comes
standard with surge and lightening protection!
The
MP TROLL 9000 is exceptionally easy to use. It has been
designed from the ground up with conveniences that you will appreciate
such as:
| |
- |
User
Replaceable batteries -- 2 D-size alkalines |
|
- |
Revolutionary
Quick-Connect cables -- Patents pending |
|
- |
Field
replaceable sensors that snap in and pop out |
|
- |
Compact
calibration cup that minimizes use of solution. It can
also be used as a storage cap for the sensors. |
|
- |
Easy-to-replace
screw-on D.O. membrane caps |
|
|
|
|
|
| |
|
 |

Pocket-Situ
for surveying and profiling. View data real-time!
Say goodbye to that expensive and heavy handheld and say hello
to new Pocket-Situ running on the Color iPAQ from Compaq. View
and download data real-time, start and stop logging operations
or take voice notes, manage your schedule, save contacts and
more. Pocket-Situ is the perfect companion to the MP TROLL 9000
for field surveying and profiling. Comes with a water-tight
case. |
Easy-to-use
Win-Situ software
is your key to harnessing the power of the MP TROLL 9000. The
Wizard-based interface guides you through each operation from
calibration to test setup. View data real-time, as a graph or
report. Some of the features include:
|
|
| - |
Intuitive
tree organization of instruments, parameters and tests.
Selecting a device in the tree displays its parameters
and tests. |
| - |
Convenient
wizards walk you through connecting new devices, setting
up tests, calibrating sensors and editing parameters. |
| - |
Context
sensitive help only displays only the information that
you need. |
| - |
Automatic
compensation for water quality parameters and
level--achieve maximum level accuracy! |
| - |
Display
all tests for a device. Icons indicate scheduled tests,
running tests, manual-start tests and completed tests. |
| - |
Take
instant readings, view data real-time, and/or log data. |
| - |
View
real-time data as a report or graph anytime. |
| - |
Win-Situ
downloads only new data, saving you time. |
| - |
Select
your choice of units. |
| - |
Convenient
readouts that display remaining memory and battery
voltage. |
| - |
Assign
a unique name to each logger, test, and site. |
| - |
And
more! |
|
Win-Situ
2000 software
Convenient
Wizards

|
| |
|
In
designing the MP TROLL 9000, as well as in our ongoing product support,
we incorporate a philosophy of providing features that our customers
will use and appreciate.Our options simply give you the choice of the
right tool for the job. The MP TROLL 9000 is also field-upgradeable
(even downhole!), should the job requirements change. Here are some of
the many optional additions to your toolkit.
|
4
Versions Offered -- a solution for every job
The
MP TROLL 9000 is offered in six versions. The versions are
scaled to meet the needs and budgets of those organizations and
individuals monitoring surface water, and those monitoring
ground water respectively. All versions share the same highly
engineered circuitry, accuracy, patented
"Quick Connect" cable system as well as lightweight,
high-quality 316L stainless steel body. The versions consist of
"Basic" and "Profiler" - instruments
specifically designed for quick basic measurements of surface
water. "Profiler XP" - designed for more extensive
quick measurements of surface water. "Professional" -
allowing for basic monitoring of either ground or surface water
with advanced memory and data logging capabilities.
"Professional XP" - designed for extensive long-term
monitoring with advanced memory and data logging capabilities.
"LTS" or Level, Temperature
and one water quality Sensor - Allows
for precision ground water measures of level, temperature and
one water quality sensor and includes advanced data logging
functions. Units with memory functions are enhanced with up to
4mb of non-volatile memory, allowing logging of over 1 million
data points. Except for the Basic unit, all versions are
upgradeable in the field should testing needs change.
|
MP
TROLL 9000 Versions
|
Basic
|
Profiler
|
Profiler
XP
|
Professional
|
Professional
XP
|
LTS
|
| Available
WQ Sensor Ports |
4 |
4 |
4 |
4 |
4 |
1 |
| Sensors |
|
|
|
|
|
|
| Dissolved
Oxygen, (%
& mg/L) |
•
|
•
|
•
|
•
|
•
|
•
|
| Digital
D.O. (No
stirring required) |
|
•
|
•
|
•
|
•
|
•
|
| Conductivity,
SC, TDS, Resistivity |
•
|
•
|
•
|
•
|
•
|
•
|
| Temperature |
•
|
•
|
•
|
•
|
•
|
•
|
| pH |
•
|
•
|
•
|
•
|
•
|
•
|
| ORP |
•
|
•
|
•
|
•
|
•
|
•
|
| pH/ORP |
•
|
•
|
•
|
•
|
•
|
|
| Salinity |
|
•
|
•
|
•
|
•
|
•
|
| Level,
Depth, Pressure |
|
•
|
•
|
•
|
•
|
•
|
| Barometric
Pressure |
|
•
|
•
|
•
|
•
|
•
|
| Nitrate |
|
|
•
|
|
•
|
|
| Chloride |
|
|
•
|
|
•
|
|
| Ammonium,
Ammonia |
|
|
•
|
|
•
|
|
| Turbidity |
|
|
•
|
|
•
|
|
| Replaceable
Sensors |
Requires
Upgrade |
• |
• |
•
|
•
|
•
|
| Data
Logging |
|
|
|
•
|
•
|
•
|
| Memory
(data points) |
|
|
|
4MB
(1.76 mil dp)
|
4MB
(1.76 mil dp)
|
4MB
(1.76 mil dp)
|
| Number
of tests stored |
|
|
|
16
|
16
|
16
|
| Linear
tests |
|
|
|
•
|
•
|
•
|
| Linear
average tests |
|
|
|
•
|
•
|
•
|
| Logarithmic
tests |
|
|
|
•
|
•
|
•
|
| Event
Tests |
|
|
|
•
|
•
|
•
|
| Min.
sampling rate (sec) |
0.5
- 2
|
0.5
- 2
|
0.5
- 2
|
0.5
- 2
|
0.5
- 2
|
0.5
- 2
|
| Telemetry
capability |
|
|
|
•
|
•
|
•
|
| Networking
capability |
|
|
|
•
|
•
|
•
|
| Automation |
|
|
|
•
|
•
|
•
|
| Upgradeable |
|
•
|
•
|
•
|
•
|
•
|
| Quick
calibration |
• |
• |
• |
• |
• |
• |
| High-accuracy
calibration |
|
• |
• |
• |
• |
• |
|
|
|