MultiRAE PLUS One to Five Gas
Monitor with VOC Detection

Build
your own personal gas monitor!
Designed
as a "building block" system, the MultiRAE can be configured
from a simple, inexpensive Oxygen/LEL monitor all the way to an affordable
five gas monitor for total protection in toxic environments. The
MultiRAE is easily reconfigured and upgraded to meet your changing needs.
MultiRAE¡¯s versatility allows it to replace a wide range of monitors,
saving training and maintenance costs. The MultiRAE is quickly and easily
changed from a sophisticated technician instrument to a simple text or
display only monitor. The same monitor can be used as personal monitor, a
hand-held sniffer, or area monitor for:
- industrial hygiene work
- emergency response
- confined space entry
Four
Gases Are Less Than Total Protection
Most confined space monitors
provide less than total protection because they miss many toxic vapors and
gases. LEL sensors measure explosivity, not toxicity. Many Volatile
Organic Compounds (VOCs) are potentially toxic at levels that are well
below the sensitivity of the LEL sensors found in most multi-gas monitors.
For example by the time that LEL sensors even
respond to gasoline vapors the air is already toxic! The MultiRAE
accurately measures low levels of VOCs without the annoyance of false
alarms that are so prevalent with other "broad-band" sensors.
Its patented VOC monitor, measures 0 - 2000 ppm of VOCs¡¯ while providing
continuous display and alarms for worker protection. Alarms can also be
set for Short Term Exposure Levels (STEL), Time Weighted Average (TWA),
Peaks and Minimums. The MultiRAE displays the exact airborne VOC levels so
that you do not have to guess when to put on respiratory protection. With
the MultiRAE you work safer, more efficiently and more comfortably because
you can go longer without respiratory protection with complete confidence
you are working in clean air.
Easy
to Use
- Compact size and
light weight for use in tight confined spaces
- Easy one button
calibration with auto zero capability
- Calibrates with gas
you already own
- Runs on alkalines,
NiCd batteries or continuously when plugged into charger or 12 V
automotive adapter
- Available as
diffusion unit or with internal sample draw pump
- Internal pump
provides quick response and remote sampling with 10-12 hours of run time
- Built-in pump
eliminates need to charge and connect separate pump module
- Programmable alarms
can be changed on the MultiRAE or from easy to use Windows¢ç software
- Internal memory holds
response factors for 37 common LEL gases and 60 common VOCs (with ability
to program custom factors)
Specifications
| GAS
MONITOR |
RANGE |
RESOLUTION |
RESPONSE
TIME (t90) |
| Oxygen |
0
- 30% |
0.1% |
15
sec |
| Combustible
gas |
0
- 100% LEL |
1% |
15
sec |
| VOCs |
0
- 200 ppm
200 - 2000 ppm |
0.1
ppm
1 ppm |
10
sec
10 sec |
| Carbon
Monoxide |
0
- 500 ppm |
1
ppm |
20
sec |
| Hydrogen
Sulfide |
0
- 100 ppm |
1
ppm |
30
sec |
| Sulfur
Dioxide |
0
- 20 ppm |
0.1
ppp |
15
sec |
| Nitric
Oxide |
0
- 250 ppm |
1
ppm |
20
sec |
| Nitrogen
Dioxide |
0
- 20 ppm |
0.1
ppm |
25
sec |
| Chlorine |
0
- 10 ppm |
0.1
ppm |
60
sec |
| Hydrogen
Cyanide |
0
- 100 ppm |
1
ppm |
60
sec |
| Ammonia |
0
- 50 ppm |
1
ppm |
150
sec |
| Phosphine |
0
- 5 ppm |
0.1
ppm |
60
sec |
| Size |
4.65"L
x 3.0"W x 1.9"H (11.8 cm x 7.6 cm x 4.8 cm) |
| Weight |
16
oz with battery (454 g) |
| Detectors |
Protected
catalytic bead for combustible gases
Interchangeable electrochemical sensors for oxygen and toxic gases
Photo ionization detector for VOCs; 10.6 eV lamp standard |
| Battery |
Rechargeable,
4.8 V, 1.4 Ah, Ni-Cd battery pack
or 4 AA alkaline battery adapter
Field replaceable
Battery charger 10 hours through built-in or external charger |
| Operating
Hours |
10
hours continuous, Unit will run and charge simultaneously |
| Display |
2
line, 16 digit LCD with LED back light automatically in dim light
or alarm condition |
| Key-Pads |
1
operation key and 2 programming keys |
| Direct
Readout |
Instantaneous
(up to 5) values Oxygen as percentage of air by volume
Combustible gas as percentage of lower explosion limit (LEL)
Toxic gases and VOCs as parts per million in air
High and low values for all sensors
STEL and TWA values of toxic gases and VOCs
Battery and shut down voltage
Date, time, elapsed time, temperature
LEL/VOC
scale (using correction factors)
|
| Intrinsic
Safety |
UL,
(cUL pending) Class 1, Division 1, Group A,B,C,D (USA &
Canada) EEx ia IIC T4 |
| Alarm |
90
dB buzzer and flashing red LED to indicate exceeded preset limits
High - 3 beeps and flashes per second
Low - 2 beeps and flashes per second
STEL and TWA - 1 beep and flash per second
Alarms latching with manual override or automatic reset
Additional diagnostic alarm and display message for low battery
and pump stall |
| Calibration |
Two
point calibration for zero and span gas |
| Datalogging |
20,000
points (64 hours, 5 channels, at one minute intervals) down load
to PC with serial number of unit, user ID and site number,
calibration date |
| Datalogging
Interval |
1
- 3600 seconds |
| Sampling
Pump |
Internal
integrated pump, flow rate 150 cc/min. |
| Temperature |
-4¨¬
to 113¨¬ F (-20¨¬ to 45¨¬C) |
| Humidity |
0%
to 95% relative humidity (non-condensing) |
¡¡
Separate alarm limit
for:
- Deficiency and enrichment of oxygen
- Low and high combustible gas concentration
- TWA, STEL, low and high for toxic gases and VOCs
| Gas |
Symbol |
STEL |
TWA |
Low |
High |
Calibration
Gas Concentration |
| Oxygen |
O2 |
n/a |
n/a |
19.5% |
23.5% |
20.9% |
| Combustible
gas |
n/a |
n/a |
n/a |
10% |
20% |
50%
LEL |
| VOCs |
n/a |
25 |
10 |
50 |
100 |
100
ppm isobutylene |
| Carbon
Monoxide |
CO |
100 |
35 |
35 |
200 |
50
ppm |
| Hydrogen
Sulfide |
H2S |
15 |
10 |
10 |
20 |
25
ppm |
| Sulfur
Dioxide |
SO2 |
5 |
2 |
2 |
10 |
5
ppm |
| Nitric
Oxide |
NO |
25 |
25 |
25 |
50 |
25
ppm |
| Nitrogen
Dioxide |
NO2 |
1 |
1 |
1 |
10 |
5
ppm |
| Chlorine |
Cl2 |
1 |
0.5 |
0.5 |
5 |
2
ppm |
| Hydrogen
Cyanide |
HCN |
4.7 |
4.7 |
4.7 |
50 |
10
ppm |
| Ammonia |
NH3 |
35 |
25 |
25 |
50 |
50
ppm |
| Phosphine |
PH3 |
1 |
0.3 |
1 |
2 |
5
ppm |
| *
All alarm limits and calibration span gas values are user
programmable |
¡¡
|